![]() Check if the connector of the harness is disconnected between LGC board (CN308) and the laser optical unit? 2. Remedy: Is the polygonal motor rotating? NO 1.Description: Polygonal motor abnormality: The polygonal motor is not rotating normally.(4) Check if any foreign matters are on the charger wire or main charger grid. (3) Check if the charger wire is broken or the main charger grid is deformed. Remedy: (1) Is the main charger installed securely? (2) Check if the spring of high-voltage supply contact point is deformed.High-voltage transformer abnormality: Leakage of the main charger is detected. Description: Process related service call.Replace the LGC board if this error occurs frequently. Check if the circuit pattern between the Engine-CPU and FROM is short- or open-circuited. Remedy: Is the “Call for Service” displayed even after the power is turned OFF and back ON ? NO Leave it and see what happens.Description: Circuit related service call.(3) Check the circuits and connectors on the RADF board, mainly IC3, IC4 and CN3, for short- and open-circuits. (2) Check if the harness connecting the original length sensor and the RADF board is open-circuited. Remedy: (1) Check if there is any foreign matter between the original length sensor and reflecting mirror. ![]() ![]() Description: Original length sensor adjustment error: The original length sensor cannot be adjusted normally when performing the code 05-356. ![]()